Search results for " AMP"
showing 10 items of 1114 documents
Variable time amplitude amplification and quantum algorithms for linear algebra problems
2012
Quantum amplitude amplification is a method of increasing a success probability of an algorithm from a small epsilon>0 to Theta(1) with less repetitions than classically. In this paper, we generalize quantum amplitude amplification to the case when parts of the algorithm that is being amplified stop at different times. We then apply the new variable time amplitude amplification to give two new quantum algorithms for linear algebra problems. Our first algorithm is an improvement of Harrow et al. algorithm for solving systems of linear equations. We improve the running time of the algorithm from O(k^2 log N) to O(k log^3 k log N) where k is the condition number of the system of equations. …
FPGA based digital lock-in amplifier for fNIRS systems
2018
Lock-In Amplifiers (LIA) represent a powerful technique helping to improve signals detectability when low signal to noise ratios are experienced. Continuous Wave functional Near Infrared Spectroscopy (CW-fNIRS) systems for e-health applications usually suffer of poor detection due to the presence of strong attenuations of the optical recovering path and therefore small signals are severely dipped in a high noise floor. In this work a digital LIA system, implemented on a Zynq® Field Programmable Gate Array (FPGA), has been designed and tested to verify the quality of the developed solution, when applied in fNIRS systems. Experimental results have shown the goodness of the proposed solutions.
Maximum Torque Per Ampere control algorithm for low saliency ratio interior permanent magnet synchronous motors
2017
This paper presents an investigation on the comparison between the Maximum Torque Per Ampere (MTPA) and the Field Orientation Control (FOC) algorithms for interior permanent magnet synchronous machines (IPMSMs). In particular, this study was carried out on a small-power IPMSM with low salience ratio. Both control algorithms have been implemented in the Matlab/Simulink environment, obtaining promising results.
High-Power Multicarrier Generation for RF Breakdown Testing
2017
Testing of satellite components for high RF power breakdown effects, such as multipactor and corona or passive-intermodulation, is a topic of growing interest in the aerospaceindustry. Switching fromthe classical single carrier approach to the more realisticmulticarrier scenario is very challenging from the experimental point of view. Themulticarrier signals, amplifiedby several RF power amplifiers, need to have controlled phase, amplitude, and frequency in each carrier. Fine tuning of the signal generator phases is required in order to compensate the phase drift occurring in the active elements of the test bed. This paper presents an efficient and low-cost technique to generate multicarrie…
Power efficiency improvements with the radio frequency H− ion source
2016
CW 13.56 MHz radio frequency-driven H(-) ion source is under development at the University of Jyväskylä for replacing an existing filament-driven ion source at the MCC30/15 cyclotron. Previously, production of 1 mA H(-) beam, which is the target intensity of the ion source, has been reported at 3 kW of RF power. The original ion source front plate with an adjustable electromagnet based filter field has been replaced with a new front plate with permanent magnet filter field. The new structure is more open and enables a higher flux of ro-vibrationally excited molecules towards the plasma electrode and provides a better control of the potential near the extraction due to a stronger separation …
Experimental comparison of two control algorithms for low-saliency ratio interior permanent magnet synchronous motors
2018
In this paper, an experimental investigation on the comparison between the Maximum Torque Per Ampere (MTPA) and the Field Orientation Control (FOC) algorithms for interior permanent magnet synchronous machines (IPMSMs) is described, analyzed and discussed. This investigation was carried out on a small-power IPMSM with low saliency ratio. More in detail, after a previous simulation study, the control techniques have been experimentally implemented and validated through means of a dSPACE® rapid prototyping system. The performances of the two algorithms have been evaluated and compared, obtaining interesting results.
A comprehensive in situ and remote sensing data set from the Arctic CLoud Observations Using airborne measurements during polar Day (ACLOUD) campaign
2019
The Arctic CLoud Observations Using airborne measurements during polar Day (ACLOUD) campaign was carried out north-west of Svalbard (Norway) between 23 May and 6 June 2017. The objective of ACLOUD was to study Arctic boundary layer and mid-level clouds and their role in Arctic amplification. Two research aircraft (Polar 5 and 6) jointly performed 22 research flights over the transition zone between open ocean and closed sea ice. Both aircraft were equipped with identical instrumentation for measurements of basic meteorological parameters, as well as for turbulent and radiative energy fluxes. In addition, on Polar 5 active and passive remote sensing instruments were installed, while Polar 6 …
Phlogopite-pargasite coexistence in an oxygen reduced spinel-peridotite ambient
2021
AbstractThe occurrence of phlogopite and amphibole in mantle ultramafic rocks is widely accepted as the modal effect of metasomatism in the upper mantle. However, their simultaneous formation during metasomatic events and the related sub-solidus equilibrium with the peridotite has not been extensively studied. In this work, we discuss the geochemical conditions at which the pargasite-phlogopite assemblage becomes stable, through the investigation of two mantle xenoliths from Mount Leura (Victoria State, Australia) that bear phlogopite and the phlogopite + amphibole (pargasite) pair disseminated in a harzburgite matrix. Combining a mineralogical study and thermodynamic modelling, we predict …
Lowering histamine formation in a red Ribera del Duero wine (Spain) by using an indigenous O. oeni strain as a malolactic starter
2016
This study demonstrates for the first time that a non-commercial selected autochthonous O. oeni strain has been used to conduct malolactic fermentation (MLF) while lowering histamine formation in the same winery. Lactic acid bacteria (LAB) were isolated from 13 vats before and after spontaneous MLF at the Pago de Carraovejas winery from the Ribera del Duero region (Spain). Only O. oeni were present, typed and characterized, and both histamine producer and non-producers existed. From the non-producers, one strain was selected to become a starter according to its genetic profile, prevalence in the different wines in the winery, resistance to alcoholic degree, resistance to high polyphenolic c…
New national and regional bryophyte records, 56
2018
WOS: 000441652000006